Horizontal air discharge chillers

Brief Description
Features
1. Compressor: Vortex type compressor, adopt international brand fully enclosed vortex type maintenance free compressor
2. Heat exchanger: 5HP or bigger model, use high efficiency shell and tube evaporator and condenser 
3. Control system: our own cotrol system, simple operation, accurate control;
4. Man-machine interface: the use of well-known brand controller and control interface, digital display, one key operation
5. Water tank:  adopt the overall design and manufacture, the built-in standard high efficiency centrifugal pipeline pump, 304 stainless steel storage tank
6. In order to adapt to the different requirements of all walks of life, the use of different series of scroll compressor, refrigeration water temperature from 15 degrees to -35 degrees, sophisticated technology to ensure the stability of the work under the extreme conditions
7. The choice of environmental protection type R407C or R134a refrigerant.

Product Description

Air-cooled chiller parameters(output temp -20℃)

Model

 UNIT

SLPA-

   3.1f

5.1f

8.1f

10.1f

12.1f

15.1f

Cooling capacity

Btu

8530.00

13989.20

24907.60

28319.60

31731.60

39920.40

RT

0.71

1.16

2.07 

2.36

2.64

3.32

Kw

2.50

4.10

7.30 

8.30

9.30

11.70

×10³Kcal/h

2.20

3.50

6.30 

7.10

8.00

10.10

 Total Power

KW

2.60

4.10

6.20

7.50

8.30

11.20

Total Current

A

4.70

7.50

11.30 

13.70

15.20

20.50

       Compressor

 Qty

set

1.00

1.00

1.00

1.00

1.00

1.00

Input power

KW

2.00

3.30

5.40

6.10

   6.90

9.60

Operation Current

A

3.60

5.90 

9.60

10.90

12.30

17.10

Condenser
Fans

Type

Efficiency copper and Blue hydrophilic aluminum Finned heat exchanger

Input power

kw

0.19

0.42

0.38

0.84

0.84

0.84

Input
Current

A

0.50

0.85

1.00

1.70

1.70

1.70

  Evaporator

 Type

  Horizontal shell-and-tube/Coil type high efficiency copper heat exchanger

  Chilled water Flow

L/min

7

12

21

24

27

34

Water pipe connection

mm

20

20

25

25

25

32

Chilled Water Pump

Type

 High efficiency, low noise

Input Power

Kw

0.37

0.37

0.37

0.55

0.55

0.75

 Head

m

17

22

23

20

18

25

Refrigerant

 Type

 R22

    Water tank Indicating Volume

Liter

70

75

100

115

145

250

Safety protection

  high and low pressure protection, overload protection, over  temperature protection, phase sequence protection, etc.

Dimensions (L*W*H)

 Length

mm

950

950

1200

1350

1400

1600

Width

mm

700

700

850

850

850

1000

  High

mm

1050

1050

1550

1550

1550

1600

 Total Weight

KG

150

200

285

350

450

600


Model

 UNIT

SLPA-

20.2f

25.2f

30.2f

40.2f

Cooling capacity

Btu

56298.00

56298.00

79840.80

107478.00

RT

4.70

5.28

   6.65

8.95

Kw

16.50

18.60

23.40

31.50

×10³Kcal/h

14.20

16.00

20.10

27.10

 Total Power

KW

14.00

16.00

21.80

29.70

Total Current

A

25.60

29.40

39.90

   54.40

       Compressor

 Qty

set

2.00

2.00

2.00

2.00

Input power

KW

12.10

13.80

19.20

25.70

 Operation Current

A

21.50

24.60

34.20

45.70

Condenser
Fans

Type

Efficiency copper and Blue hydrophilic aluminum Finned heat exchanger

Input power

KW

1.14

1.50

2.52

1.14


Input
Current

A

3.00

3.84

5.10

3.00




Evaporator

 Type

Horizontal shell-and-tube/Coil type high efficiency copper heat exchanger


  Chilled water Flow

L/min

47

53

67

90


Water pipe connection

mm

32

32

40

40



Chilled Water Pump

Type

High efficiency, low noise


Input Power

Kw

0.75

1.10

1.10

1.50


Head

m

25

24

22

22


Refrigerant

 Type

                                       R22 


    Water tank Indicating Volume

Liter

270

320

360

400



Safety protection

high and low pressure protection, overload protection, over temperature protection, phase sequence protection, etc.



Dimensions (L*W*H)

 Length

mm

1950

2100

2200

2450

Width

mm

1250

1250

1250

1350

  High

mm

1600

1600

1850

2050

 Total Weight

KG

830

1050

1250

1350


Note:
1, the table refrigeration conditions: chilled glycol water inlet temperature -15 ℃, cold water outlet temperature -20 ℃, ambient temperature 35 ℃, the use of ambient temperature range -7 ℃ ~ 43 ℃;
2, this series of units used in low temperature conditions, to use 45% of  the glycol for antifreeze coolants;
3, the series unit uses imported from Europe hermetic compressors, superior performance, strong anti-strike capability liquid; 
4, standard power supply: 380V / 3N-50HZ, voltage fluctuation allowed ± 5%, frequency fluctuation ± 2%; 
5, host the actual head of the pump head minus head losses within the host. (1mH2O = 9.8KPa);
6, In addition to the specifications and requirements, we can provide non-standard products according to customer requirements

Product Tags