Features 1. Compressor: adopt international brand semi-closed ...
• Unique floating coil design avoids leakage caused by thermal...
Project: |
Type: |
Chilled water AHU |
|||||
Location |
Deck 7 |
Serving: |
FWD Wheelhouse |
||||
Type |
Centrifugal, backward curve |
Mixing section |
|||||
Air discharge position |
Front |
||||||
Return air position |
Back |
||||||
Fan brand |
KRUGER/Nicotra |
||||||
Fan model |
|||||||
Drive method |
V-Belt Drive |
||||||
Anti vibration |
Spring Isolater |
||||||
Air flow |
CMH |
5510 / 2755 (2-Speed) |
|||||
External Static Pressure |
Pa |
400 |
|||||
Description |
Tubular tube with fin type of SS304 |
Electric Heating |
|||||
Capacity |
KW |
35kW (2-stage) |
|||||
Power supply |
440V/3PH/60HZ |
||||||
Type |
Atomised mist |
Humidification |
|||||
Power supply |
230V/1P/60hz or 440V/3P/60hz |
||||||
Capacity |
litre/hr |
20 l/hr |
|||||
Washable Pre filter |
Disposable type |
Filter |
|||||
Type |
Primary type: EU5 |
||||||
Power supply |
440V/3PH/60HZ |
Fan motor |
|||||
Enclosure class |
IP55, Insulation F |
||||||
Brand |
ABB/Siemens |
||||||
Space heater |
Included |
||||||
Fan speed |
rpm |
||||||
Motor power |
KW |
||||||
Motor speed |
rpm |
1390 |
|||||
Pole |
4 |
||||||
Cooling capacity |
KW |
59.0 |
Cooling coil |
||||
Inlet/outlet water |
℃ |
7 / 12 |
|||||
Water Flow |
m3/h |
||||||
Pipe connection |
|||||||
On coil air temp |
℃DB |
26degC / 72%RH |
|||||
Off coil air temp |
℃DB |
13degC / 90%RH |
|||||
Construction |
Copper tubes with heresite coated aluminum fins, stainless steel frame SS304 |
||||||
Material |
stainless steel sheet SS304 drain tray, thickness 1.0mm |
Drain tray |
|||||
Connection |
Both side,DN32 |
||||||
Hot dip galvanized steel ceiling mounted angle bar |
Unit foundation |
||||||
Multiple side |
Access door |
||||||
Aluminium Alloy Frame ,50mm non-flameable PU Insulation,Inside: Powder coated sheet external 1.0mmthick, internal 1.0mmthick |
Frame and panel |
||||||
mm |
H<750mm |
Dimensions(L*W*H) |
|||||
kg |
Net weight |
||||||
kg |
Gross weight |
||||||
Remarks: |
|||||||
All wiring and cable to be suitable for marine application |
|||||||
All wiring to be routed to termination box of IP55 at AHU |
|||||||
Air flow pressure switch to be provided |
|||||||
AHU interior lighting to be provided |
|||||||
AHU window port to be provided |
|||||||
Electric heater to include overload protection and adjustable overheating protection |
|||||||
Inlet/discharble manual dampers to be provided |
|||||||
Electrical control panel to be provided |
|||||||
Electrical control including hourly run meter, remote alarm signal, remote on/off capability, temperature control for heating, cooling, humidity control |